<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22101</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Measured thickness is %d (%i mil), Matched thickness is %i (%i mil) - RESUME = Matched
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Selecting resume for a large discrepancy may cause the scaling factor applied to be
incorrect.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
If the value reported is close to what was loaded select resume, else cancel the image
and double check the plate thickness.
</text></DescriptionText>
</OperatorAction>
<Cause>
The head stage has finished zeroing and has calculated the plate thickness.
The plate thickness does not agree with the submitted plate thickness within tolerance.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:55 2008 PST
</Updated>
<Links>
</Links>
</Error>